An adversary may attempt to block indicators or events typically captured by sensors from being gathered and analyzed. This could include maliciously redirecting [1] or even disabling host-based sensors, such as Event Tracing for Windows (ETW),[2] by tampering settings that control the collection and flow of event telemetry. [3] These settings may be stored on the system in configuration files and/or in the Registry as well as being accessible via administrative utilities such as PowerShell or Windows Management Instrumentation.
ETW interruption can be achieved multiple ways, however most directly by defining conditions using the PowerShell Set-EtwTraceProvider
cmdlet or by interfacing directly with the Registry to make alterations.
In the case of network-based reporting of indicators, an adversary may block traffic associated with reporting to prevent central analysis. This may be accomplished by many means, such as stopping a local process responsible for forwarding telemetry and/or creating a host-based firewall rule to block traffic to specific hosts responsible for aggregating events, such as security information and event management (SIEM) products.
ID | Name | Description |
---|---|---|
S0377 | Ebury |
Ebury can hook logging functions so that nothing from the backdoor gets sent to the logging facility.[4] |
S0579 | Waterbear |
Waterbear can hook the |
ID | Mitigation | Description |
---|---|---|
M1022 | Restrict File and Directory Permissions |
Ensure event tracers/forwarders [6], firewall policies, and other associated mechanisms are secured with appropriate permissions and access controls. |
M1054 | Software Configuration |
Consider automatically relaunching forwarding mechanisms at recurring intervals (ex: temporal, on-logon, etc.) as well as applying appropriate change management to firewall rules and other related system configurations. |
M1018 | User Account Management |
Ensure event tracers/forwarders [6], firewall policies, and other associated mechanisms are secured with appropriate permissions and access controls and cannot be manipulated by user accounts. |
ID | Data Source | Data Component |
---|---|---|
DS0017 | Command | Command Execution |
DS0013 | Sensor Health | Host Status |
DS0024 | Windows Registry | Windows Registry Key Modification |
Detect lack of reported activity from a host sensor. Different methods of blocking may cause different disruptions in reporting. Systems may suddenly stop reporting all data or only certain kinds of data.
Depending on the types of host information collected, an analyst may be able to detect the event that triggered a process to stop or connection to be blocked. For example, Sysmon will log when its configuration state has changed (Event ID 16) and Windows Management Instrumentation (WMI) may be used to subscribe ETW providers that log any provider removal from a specific trace session. [3] To detect changes in ETW you can also monitor the registry key which contains configurations for all ETW event providers: HKLM\SYSTEM\CurrentControlSet\Control\WMI\Autologger\AUTOLOGGER_NAME{{PROVIDER_GUID}}